Skip to main content
  1. Both the front and back Case of the Nabi Jr. had low levels of metals and halogens including bromine and chlorine chemistry flame retardanst. Both the front and back Case of the Nabi Jr. had low levels of metals and halogens including bromine and chlorine chemistry flame retardanst. Both the front and back Case of the Nabi Jr. had low levels of metals and halogens including bromine and chlorine chemistry flame retardanst.
    • Both the front and back Case of the Nabi Jr. had low levels of metals and halogens including bromine and chlorine chemistry flame retardanst.

  2. For each tablet we tested a variety of integrated circuit components, the printed circuit board substrate, wire, solder and other components. The Circuit Board of the Nabi Jr. had high levels of bromine.  The highest level detected was 16,325 parts per million (ppm).  This  high level of bromine was detected in the circuit board substrate material itself.  Image #3 below shows some of the other components which were tested.  Complete test results are available on our product detail page. The Circuit Board of the Nabi Jr. had high levels of bromine.  The highest level detected was 16,325 parts per million (ppm).  This  high level of bromine was detected in the circuit board substrate material itself.  Image #3 below shows some of the other components which were tested.  Complete test results are available on our product detail page.
    • For each tablet we tested a variety of integrated circuit components, the printed circuit board substrate, wire, solder and other components.

    • The Circuit Board of the Nabi Jr. had high levels of bromine. The highest level detected was 16,325 parts per million (ppm). This high level of bromine was detected in the circuit board substrate material itself. Image #3 below shows some of the other components which were tested. Complete test results are available on our product detail page.

  3. The interior and exterior of the screen was tested and found to have low levels of heavy metals and halogens.  Complete chemical test results for all components are available. The interior and exterior of the screen was tested and found to have low levels of heavy metals and halogens.  Complete chemical test results for all components are available.
    • The interior and exterior of the screen was tested and found to have low levels of heavy metals and halogens. Complete chemical test results for all components are available.